金属硫蛋白
英文名称: Metallothionein MT
型号:null    产品货号: CG091201
价格:请致电:010-57128832,18610462672
品牌: usa

CAS号: 73767-16-5 英文名称: METALLOTHIONEIN 中文名称: 金属硫蛋白中文同义词: 金属硫蛋白;Metallothionein

 
产品介绍
[产品名称]
产品名:金属硫蛋白
英文名:Metallothionein (MT)
[来源]、兔肝
[性状]  本品为白色冻干品
MTs 纯度  >95%
巯基活性>95%
[检测报告与方法]  SDS聚丙烯酰胺电泳       HPLC-DEAE
注意事项:
1,金属硫蛋白的适用PH范围:PH3-8
2,金属硫蛋白不宜用于强氧化条件下
3,耐热80度3分钟
用途:生化研究,富含半胱氨酸的小分子金属结合蛋白。
贮存] 4度大于1年,-20度1-3年,-70度3-5年

/STRONG>


3. 所有件都无毒可酒精消毒。


4. 柱腔的几何形状提供了极好的气体分布。


5. 可靠的气密性密封100%控制气体含量和交


6. 可以放置在二氧化碳培箱内与其他条件的形成

三、 使用方法将二氧化碳按需要的比例充入气罐中
 
用气管接气罐和装置可以用流量计进监测 放入要培胞板、胞培皿等调节二氧化碳培箱的温、湿度。密封扣件行培扣件取出液。
 
品的格参数

l Detailed SpecifiItem Hypoxia Modular Incubator Chamber
l Company Billups-Rothenberg Inc.
l Price Iinqure
l Catalog Number MIC-101
l Catalog Number MIC - 101
l Exterior Dimensions Dia 31cm (12in); Height 11cm (4.7in)
l Interior Dimensions Diameter of Trays: 26.7 cm (10.5 in)
l Quantity EA
l Capacity 35 to 100 mm Dishes, 96 Well Plates, Flasks

五、参考文献
1.Two Novel Missense Mutations of the HFE Gene (I105T and G93R) and Identification of the S65C Mutation in Alabama Hemochromatosis Probands* 1
[PDF]from lbtek.comJC Barton, R Sawada-Hirai, BE Rothenberg- Blood Cells,Molecules, , 1999 - Elsevier
... Probands *1. James C. Barton a , f1 , Ritsuko Sawada-Hirai b , Barry E. Rothenbergc and Ronald T. Acton c. a Southern Iron Disorders Center, Birmingham, Alabama. b Billups-Rothenberg, Inc. San Diego, California. c Immunogenetics ...
Cited by 150 - Related articles - BL Direct - All 14 versions

2.Preconditioning of the tumor vasculature and tumor cells by intermittent hypoxia: implications for anticancer therapies
[HTML]from aacrjournals.orgP Martinive, F Defresne, C Bouzin, J Saliez, F Lair- Cancerresearch, 2006 - AACR
... To reach and control hypoxia conditions, cells were placed in a modular incubator chamber(Billups Rothenberg, Inc., Del Mar, CA) and flushed for 10 minutes with a gas mixture of 5% CO

2 -95% N 2 ; the final medium pO 2 value was consistently measured below the 0.5% to 1 ...
Cited by 61 - Related articles - BL Direct - All 9 versions

3.The pH-dependent membrane association of procathepsin L is mediated by a 9-residue sequence within the propeptide.
[PDF]from jbc.orgGF McIntyre, GD Godbold- Journal of Biological Chemistry, 1994 -ASBMB
... inhibitor E-64, dithiothreitol, and HEPES were from Boehringer Mannheim; ECL WesternBlotting
Detection Re- agents and don key anti-rabbit serum conjugated to horseradish peroxi- dase were

from Amersham Corp.; the HotBox System was from Billups- Rothenberg, Del Mar ...
Cited by 55 - Related articles - BL Direct - All 6 versions

4.Intersection of interferon and hypoxia signal transduction pathways in nitric oxide-induced tumor apoptosis

成立于1971年美国比卢普斯罗森堡公司(Billupsrothenberg)的缺氧、常氧、高氧模块化孵化室系统已用于世界各地四十年。

该公司生产的缺氧\高氧培养系统可自定义的混合气体和温度组织培养条件.密闭室已被证明安全、可靠,每个单元是一个自包含的孵化器,使您能够创建所需的组织培养的各种环境 (气体浓度和湿度),已广泛应用于北美各大实验室和研究机构。

该产品获美国专利,在已发表的论文中引用率在同类产品中是属于最高的,并逐渐被全球的实验研人员所使用。

2010年起世联博研获得卢普斯-罗森堡公司授权在中国大陆地区独家经销缺氧\高氧培养小室及相关产品,并负责该区域售前咨询和售后的技术问题。 世联博研竭诚为全国 研工作者提供专业、周到的服务!

MIC-101模块化培养孵化室:

MIC-101 细胞厌氧培养装置(低氧培养利器)

特点:

·O型环、聚碳酸酯密封安全可靠

·腔室独立,避免避免交叉感染

·腔可堆叠交错搅拌节省空间

·圆柱腔体状极好气体分布

组织培养器量皿容量:

84x35mm培养皿


27x60mm培养皿

12x100mm培养皿


09x96孔微培养板

尺寸:

外形尺寸:直径31CM(12英寸)


高:11cm(4.7英寸)

内盘直径:26.7cm(10.5英寸)

托盘间隙:2.3cm(0.9英寸)

·多个多功能托盘方便盛放培养皿、试管、组织培养瓶、微培养板等

·所有部件无毒,可酒精消毒

·盖与Marman夹具设计便捷,可轻松访问

单流量计/双流量计系统:

单流量计/双流量计系统:

流量计包括单流量计和双流量计2种,它能帮用户确定何时获得了100%气体交换。如果您使用的是模块化培养室(MIC-101)创建一个缺氧,高氧或常氧环境,我们建议您购买我们的流量计之一。这两种类型的流量计都可以把流量调整为325升/分钟(或0.1-10LPM)。单个流量计(SFM3001)被用来控制预混合气体的流量;双流量计(DFM3002)除了控制的气体流率还可以用来混合气体(双流量计被用作检测与氧气的组合).每个培养室的体积约8升。

热箱系统(Hot Box System)

热箱系统(Hot Box System)

热箱系统(Hot Box System)消除了***性气体对人员和设备的危害。
将之隔离标记实验中,让您重拾充分利用CO2培养箱作用。在热箱系统可更安全进行实验。
热箱系统包括:模块化培养室、流量计、静态热过滤器、排热过滤器、热烟道。





The Hot Box System eliminates the hazard of contamination of personnel and equipment by radioactive gases. It isolates labeling experiments and allows you to regain full use of your CO2 incubator. Conduct experiments safely in the Hot Box System.


With millions of contaminating counts generated during typical labeling experiments, incubators must be decontaminated after every use. You can now conduct safe [35S] labeling experiments at a fraction of present cost!

The Hot Box System is compact and easy to use. Just place labeling experiment and a Static Hot Filter and flusk unit with desired gas mixture. Seal unit, remove Exhaust Hot Filter, and Flow Meter and place the Hot Box in a controlled temperature environment. To remove the labeled cells, reattach Exhaust Hot Filter and Flow Meter, and purge again. Dispose of both filters. It's that simple!



Modular Incubator Chamber

Used worldwide for two decades, this airtight chamber has been proven safe and reliable for in vitro fertilization, HIV isolation, hypoxia, organ culture and the culturing of a host of cell lines. Each unit is a self-contained incubator enabling you to create the desired tissue culture environment (gas concentrations and humidity).
货号品名价格
MIC-101
1 ea. Modular Incubator Chamber询价
MIC-101
2 or more Modular Incubator Chambers询价
One Modular Incubator Chamber consists of the following parts: Lid, base, 3 trays, stainless steel clamp, O-ring, 2 tubing clamps and tygon tubing.
Conversion Kits For MIC-101:
货号品名价格
HMIC3S
Conversion Kit with Single Flow Meter.询价
Kit includes:
1 ea. Single Flow Meter, 1 ea. Hot Filters (5 exhaust and 5 static filter), 1 ea. Hot Chimney,2 ea. Air Filter, 1 ea. Static Filter Post,1 ea. O-Ring
货号品名价格
HMIC3
Conversion Kit With Dual Flow Meter询价
Kit Includes:
1 ea. Dual Flow Meter, 1 ea. HOT FILTERS (5 exhaust and 5 static filter) , 1 ea. HOT CHIMNEY, 2 ea. Air Filter, 1 ea. Static Filter Post, 1 ea. O-Ring


Flow Meters
Regulation of gas flow during purging is required to allow sufficient reaction time for irreversible binding of [35S]-volatile with the specially formulated charcoal in the Exhaust Hot Filter. Use Single Flow Meter with pre-mixed gases or Dual Flow Meter for on-site mixing of gases.
货号品名价格
SFM3001
Single Flow Meter (for premixed gases)询价
DFM3002
DFM3002 Dual Flow Meter (for mixing gases)询价

Static Hot Filters
Placed inside the chamber during experiments, the Static Hot Filter captures 85-90% of radioactive gases.

Exhaust Hot Filters

Any radioactive gases which have not had time to attach to the Static Hot Filter during the labeling experiment are trapped completely by the Exhaust Hot Filter during purging.


Hot Chimney

Used while thawing [35S]-Met/Cys, the Hot Chimney removes contaminating gases from manufacturer's reagent vial, reducing personnel exposure to radioactive gases during experimental set-up. It is designed with a Leur-Lock for safe attachment of syringe needle.

Hot-Box-System:

货号品名价格
HBS2001S
The Hot Box System With Single Flow Meter询价
System includes:
1 ea. MIC-101 (Modular Incubator Chamber), 1 ea. Hot Filters (1 exhaust and 1 static filter) , 1 ea. Hot Chimney ,1 ea. Single Flow Meter ,2 ea. Air Filter ,1 ea. Static Filter Post
NOTE: HOT FILTERS MUST BE USED IN CONJUNCTION WITH A FLOW METER. FAILURE TO DO SO MAY CAUSE BACK PRESSURE TO INCREASE RESULTING IN FAILURE OF SYSTEM.
货号品名价格
HBS2001D
The Hot Box System With Dual Flow Meter询价
System includes:
1 ea. MIC-101 (Modular Incubator Chamber), 1 ea. Hot Filters (1 exhaust and 1 static filter), 1 ea. Hot Chimney, 1 ea. Dual Flow Meter, 2 ea. Air Filter, 1 ea. Static Filter Post
NOTE: HOT FILTERS MUST BE USED IN CONJUNCTION WITH A FLOW METER. FAILURE TO DO SO MAY CAUSE BACK PRESSURE TO INCREASE RESULTING IN FAILURE OF SYSTEM.


To Reorder Filters:
Part Number:Description:Unit Cost:
HFS2020
1 Set of 5 exhaust and 5 static Hot Filters询价
HCS2030
1 Set of 5 Hot Chimneys询价
HFS2021
1 Set of 6 air filters询价

replacement parts:

货号品名价格
102
Lid (polycarbonate)询价
103
Base (polycarbonate)询价
104
Tray (polycarbonate)询价
105
Stainless Steel Ring Clamp询价
106
O-Ring询价
107
Tubing Clamp (10 clamps with tubing)询价