极性脂混标
英文名称: POL Mix 71
型号:null    产品货号: 咨询甄准
价格:请致电:010-57128832,18610462672
品牌: 瑞典
试剂级别: 超纯级

极性脂混标—上海甄准

***脂的醇部分或者是甘油,或者是鞘氨醇,故可分成甘油***脂和鞘***脂两类,它们都是极性脂。极性脂由极性部分(叫做极性头)和非极性部分(叫做非极性尾)组成。

上海甄准生物提供极性脂混标由天然或合成的***脂、鞘脂、神经节苷脂组成,用于TLC和HPLC。

产品信息:

货号

品名

英文品名

描述

规格

02161036

极性脂混标

POL Mix 71

Cardiolipin (CL) (bovine)
PC (egg)  
PE (egg)  
PI (wheat germ (Na salt)  
PS (spinal cord, bovine)  
PG (egg PC)
,组分纯度98+%

10 mg

更多产品,更多优惠!请联系我们!
上海甄准生物科技有限公司
免费热线:400-002-3832
电话:021-6840 4353
传真:021-5897 9353
客服手机/QQ15800340161
客服手机/QQ13795317828
客服手机/QQ13512172575
客服手机/QQ13818641861
客服手机/QQ13917991872
客服手机/QQ13916577892
技术支持热线/QQ13651665725
服务监督与投诉:18918753302
官网:www.zzstandard.com
E
yangshuyan@zzstandard.com

000pt; font-family:宋体; ">

6. 加酶:每孔加入酶标试剂50μl,空白孔除外

7. 温育:操作同3

8. 洗涤:操作同5

9. 显色:每孔先加入显色剂A50μl,再加入显色剂B50μl,轻轻震荡混匀,37℃避光显色15分钟. 

10. 终止:每孔加终止50μl,终止反应(此时蓝色立转黄色)

11. 测定:以空白空调零,450nm波长依序测量各孔的吸光度(OD值) 测定应在加终止液后15分钟以内进行。

注意事项:

1. 试剂盒从冷藏环境中取出应在室温平衡15-30分钟后方可使用,酶标包被板开封后如未用完,板条应装入密封袋中保存。

2. 浓洗涤液可能会有结晶析出,稀释时可在水浴中加温助溶,洗涤时不影响结果。

3. 各步加样均应使用加样器,并经常校对其准确性,以避免试验误差。一次加样时间最好控制在5分钟内,如标本数量多,推荐使用排枪加样。

4. 请每次测定的同时做标准曲线,最好做复孔。如标本中待测物质含量过高(样本OD值大于标准品孔第一孔的OD值),请先用样品稀释液稀释一定倍数(n倍)后再测定,计算时请最后乘以总稀释倍数(×n×5)。

5. 封板膜只限一次性使用,以避免交叉污染。

6. 底物请避光保存。

7. 严格按照说明书的操作进行,试验结果判定必须以酶标仪读数为准.

8. 所有样品,洗涤液和各种废弃物都应按传染物处理。

9. 本试剂不同批号组分不得混用。

10. 如与英文说明书有异,以英文说明书为准。

计算

以标准物的浓度为横坐标,OD值为纵坐标,    

在坐标纸上绘出标准曲线,根据样品的OD      

值由标准曲线查出相应的浓度;再乘以稀释      

倍数;或用标准物的浓度与OD值计算出标      

准曲线的直线回归方程式,将样品的OD      

代入方程式,计算出样品浓度,再乘以稀释      

倍数,即为样品的实际浓度。                  

  

                                              

 

(此图仅供参考)

 

 

 

试剂盒性能:

1.样品线性回归与预期浓度相关系数R值为0.92以上。

2.批内与批间应分别小于9%15%

 

检测范围:                                              

4μg/ml -100μg/ml                                     

                            

保存条件及有效期:

1.试剂盒保存:2-8

2.有效期:6个月

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR RESEARCH USE ONLY

Human apoprotein C3

 

Drug Names

Generic NameHuman apoprotein C3 (apo-C3) ELISA Kit.

Purpose

This kit allows for the determination of apo-C3 concentrations in Human serum, blood plasma, and other biological fluids.

Principle of the assay

The kit assay Human apo-C3 level in the sampleuse Purified Human apo-C3 antibody to coat microtiter plate wells, make solid-phase antibody, then add apo-C3 to wells, Combined apo-C3 antibody which With HRP labeled , become antibody - antigen - enzyme-antibody complex, after washing Completely, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of apo-C3 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

 

 

 

 

 

 

 

Materials provided with the kit

Materials provided with the kit

48determinations

96 determinations

Storage

User manual

1

1

 

Closure plate membrane

2

2

 

Sealed bags

1

1

 

Microelisa stripplate

1

1

2-8

Standard135μg/ml

0.5ml×1 bottle

0.5ml×1 bottle

2-8

Standard diluent

1.5ml×1 bottle

1.5ml×1 bottle

2-8

HRP-Conjugate reagent

3ml×1 bottle

6ml×1 bottle

2-8

Sample diluent

3ml×1 bottle

6ml×1 bottle

2-8

Chromogen Solution A

3ml×1 bottle

6ml×1 bottle

2-8

Chromogen Solution B

3ml×1 bottle

6ml×1 bottle

2-8

Stop Solution

3ml×1 bottle

6ml×1 bottle

2-8

wash  solution

20ml×20 fold

×1bottle

20ml×30 fold

×1bottle

2-8

Specimen requirements

1. serum- coagulation at room temperature 10-20 minscentrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

2. plasma-use suited EDTA or citrate plasma as an anticoagulant,mix 10-20 mins ,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

3. Urine-collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again. The Operation of Hydrothorax and cerebrospinal fluid Reference to it.

4. cell culture supernatant-detect secretory components, collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant,detect the composition of cells, Dilut cell suspension with PBSPH7.2-7.4, Cell concentration reached 1 million / ml, repeated freeze-thaw cycles, damage cells and release of intracellular components, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

5. Tissue samples- After cutting samples, check the weight,add PBSPH7.2-7.4, Rapidly frozen with liquid nitrogen, maintain samples at 2-8 after melting,add PBSPH7.4, Homogenized by hand or Grinders, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant.

6. extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it cant, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.

7. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

Assay procedure

1.Dilute and add sample to Standard: set 10 Standard wells on the ELISA plates coated, add Standard 100μl to the first and the second well, then add Standard dilution 50μl to the first and the second well, mix; take out 100μl form the first and the second well then add it to the third and the forth well separately. then add Standard dilution 50μl to the third and the forth well ,mix ; then take out 50μl from the third and the forth well discard, add 50μl to the fifth and the sixth well ,then add Standard dilution 50μl to the fifth and the sixth well, mix ; take out 50μl from the fifth and the sixth well and add to the seventh and the eighth well, then add Standard dilution 50μl to the seventh and the eighth well ,mix ; take out 50μl from the seventh and the eighth well and add to the ninth and the tenth well, add Standard dilution 50μl to the ninth and the tenth well, mix , take out 50μl from the ninth and the tenth well discard(add Sample 50μl to each well after Diluting ,(density: 90μg/ml 60μg/ml ,30μg/ml15μg/ml7.5μg/ml)

2.add sampleSet blank wells separately (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.

4.Configurate liquid: 30-fold (or 20-fold)wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well. 

7.incubateOperation with 3.

8.washingOperation with 5.

9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

Important notes

1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 mins, if the number of sample is much , recommend to use Volley .

4. if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.

6. The substrate evade the light preservation.

7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

8. All samples, washing buffer and each kind of reject should according to infective material process.

9. Do not mix reagents with those from other lots.

 

Calculate

 

 

 

 

 

 

 

 

 

Assay range

4μg/ml -100μg/ml

 

Storage and validity

1Storage:  2-8.

2validity: six months.