肾细胞癌等组织芯片OD-CT-UrKid01-002
英文名称: tissue microarray
型号:: OD-CT-UrKid01-002
价格:请致电:010-57128832,18610462672
品牌: 上海    产品商标: 上海芯超生物

各类型肾癌200例(以肾透明细胞癌为主)。肾癌旁相对正常10例。其它癌40例每例2点。 

ht: windowtext 0.5pt solid">PGEX-5X-2 28-9545-55 PGEX-5X-3 28-9546-46 PGEX-2TK 28-9546-48 PGEX-6P-1 VECTOR 28-9546-50 PGEX-6P-2 VECTOR 28-9546-51 PGEX-6P-3 VECTOR 28-9546-53 PGEX-2T 25 UG WI/DI 28-9546-54 PGEX-3X 25 UG WI/DI 28-9546-56 PGEX-1LT ECOR I/BAP 11-0033-99 HIS GRAVITRAP 11-0034-00 HIS BUFFER KIT 27-4710-01 ANTI-HIS ANTIBODY 28-4009-89 HIS MULTITRAP HP 28-4009-90 HIS MULTITRAP FF 28-4013-53 HIS SPINTRAP 28-4039-43 COLLECTION PLATE 28-9321-71 His SpinTrap Kit 27-1583-01 LIGHT PRIMER MIX 27-1586-01 HEAVY PRIMER MIX 27-1588-01 LINKER-PRIMER MIX 27-1589-01 RS PRIMER MIX 27-9420-01 ANTI-M13 MONOCLONAL ANTIBODY 27-9421-01 HRP/ANTI-M13 MONOCLNL CONJUG.

详情请查询以下网址:http://www.gelifesciences.com/webapp/wcs/stores/servlet/productById/zh/GELifeSciences-us/28952359

GST SpinTrap

GST SpinTrap columns are designed for rapid small-scale purification of GST-tagged proteins directly from clarified or unclarified cell lysates

 

GST SpinTrap columns are designed for rapid small-scale purification of GST-tagged proteins directly from clarified or unclarified cell lysates. GST-tagged proteins can be recovered under mild elution conditions (10 mM glutathione), which preserves the functionality of the proteins, and more than 90% purity can be obtained in a single step. GST SpinTrap columns are suitable for purification of multiple samples in parallel, for example in screening experiments such as evaluation of chromatography media, growth temperature, culture density, and other variables to find optimal conditions for expression.

 

GST SpinTrap columns are designed for use in a microcentrifuge. Each column contains 50 μl of Glutathione Sepharose 4B, enough for purifying up to 500 μg of recombinant GST and each package contains 50 columns. For increased convenience, GST Buffer Kit contains stock solutions of the buffers needed for purification of GST-tagged proteins.

GST SpinTrap — Technical Specifications

Complete Packsize 50 x 50 µl
Bed Volume 50 µl
Binding Capacity/Column Up to 500 µg recombinant glutathione S-transferase (rGST)
Storage Conditions 4 to 30°C, PBS and 0,05% Kathon CG/ICP Biocide
   
Media  
Ligand Glutathione
Average Particle Size 90 μm
Matrix Agarose, 4%
Particle Size 45 µm-165 µm
Binding Capacity/ml Chromatography Medium > 25 mg horse liver GST/ml medium1)
pH stability Working Range 4-13
pH stability Cleaning 4-13
Storage Conditions 4 to 30°C, 20% Ethanol
Chemical Stability All commonly used aqueous buffers
1)Binding of GST to glutathione is flow-rate dependent and lower flow rates often increase the binding capacity. This is important to consider during sample loading and elution.