17-0407-03 | HiTrap Heparin HP 5x5ml | 17-0408-01 | HITRAP CHELATING HP, 5 X 1 ML | 17-0409-01 | HITRAP CHELATING HP, 1 X 5 ML | 17-0409-03 | HITRAP CHELATING HP 5 X 5 ML | 17-0409-05 | HITRAP CHELATING HP 100 X 5 ML | 17-0412-01 | HITRAP BLUE HP, 5 X 1 ML | 17-0413-01 | HITRAP BLUE HP, 1 X 5 ML | 17-0716-01 | HITRAP NHS-ACTIV HP, 5 X 1ML | 17-0716-30 | HiTrap NHS-activated HP, 180 x | 17-0717-01 | HITRAP NHS-ACTIV HP, 1 X 5 ML | 17-0920-03 | HITRAP IMAC HP, 5 X 1 ML | 17-0920-05 | HITRAP IMAC HP, 5 X 5 ML | 17-0921-02 | HITRAP IMAC FF, 5 X 1ML | 17-0921-04 | HITRAP IMAC FF, 5 X 5 ML | 17-0978-13 | HITRAP BUTYL-S FF, 5 X 1ML | 17-0978-14 | HITRAP BUTYL-S FF, 5 X 5ML | 17-1128-01 | MABTRAP KIT | 17-1151-01 | HITRAP SP HP, 5 X 1 ML | 17-1152-01 | HITRAP SP HP, 5X5 ML | 17-1153-01 | HITRAP Q HP, 5 X 1 ML | 17-1154-01 | HITRAP Q HP 5X5 ML | 17-1351-01 | HITRAP PHENYL HP, 5 X 1ML | 17-1353-01 | HITRAP PHENYL FF (LS), 5X1ML | 17-1355-01 | HITRAP PHENYL FF (HS),5 X 1ML | 17-1357-01 | HITRAP BUTYL FF, 5 X 1 ML | 17-1359-01 | HITRAP OCTYL FF, 5 X 1 ML | 17-1408-01 | HITRAP DESALTING, 5X5ML | 17-5053-01 | HITRAP Q FF, 5 X 1 ML | 17-5054-01 | HITRAP SP FF, 5 X 1 ML | 17-5055-01 | HITRAP DEAE FF 5 X 1 ML | 17-5056-01 | HITRAP CM FF, 5 X 1 ML | 17-5079-01 | HITRAP RPROTEIN A FF, 5X1ML | 17-5079-02 | HITRAP RPROTEIN A FF, 2 X 1 ML | 17-5080-01 | HITRAP RPROTEIN A FF, 1X5ML | 17-5080-02 | HITRAP RPROTEIN A FF, 5 X 5 ML | 17-5110-01 | HITRAP IGM PURIFICATION 5X1ML | 17-5111-01 | HITRAP IGY PURIFICATION 1X5 ML | 17-5112-01 | HITRAP STREPTAVIDIN HP5X1 ML | HiTrap™ Heparin HP Columns - Prepacked with Heparin Sepharose™ High Performance for purification of proteins such as DNA-binding proteins, coagulation factors, lipoproteins, and protein synthesis factors.
- Stable over pH 5-10 and tolerates all commonly used aqueous buffers
HiTrap™ Heparin HP ColumnsTechnical Information
Immobilized heparin has two main modes of interaction with proteins. It can operate as an affinity ligand; e.g. in its interaction with coagulation factors. Heparin also functions as a high capacity cation exchanger, due to its anionic sulfate groups. Gradient elution with salt is most commonly used in both cases. Heparin is coupled to the Sepharose™ High Performance base matrix via the N-hydroxysuccinamide coupling method, to give high capacity, performance, and low leakage levels. HiTrap™ Heparin is delivered in 0.2 M NaCl with 20% ethanol as bacteriostatic agent. Store HiTrap™ Heparin columns equilibrated with 25 ml 20% ethanol or a buffer containing a bacteriostatic agent. Equilibration is easily done with a syringe and the supplied luer adapter. Seal the column with the supplied stopper and domed nut. The recommended storage temperature is 4 to 30°C.
TECHNICAL SPECIFICATIONS | Ligand | Porcine heparin | Ligand coupling method | Reductive amination | Ligand density | » 10 mg heparin/ml medium | Matrix | Highly cross-linked agarose, 6% | Average particle size | 34 μm | pH stability | pH 5-10 | Storage | 20% ethanol | Storage temperature | 4°C to 30°C | Purification of Antithrombin III from bovine plasma.
SDS -PAGE electrophoresis with PhastSystem™ and PhasGel Gradient 8-25, silver stained. |