Programmable 2-Channel Bipolar Precision High Stability Temperature Controller
TC2-80-150/BTC-2-100,
Low Electrical Noise
Can be used with Temperature controlled microscope stages.
Provides higher stability required
for some sensitive applications, nano/piezo positioning, confocal or AFM imaging for example. Flexible controls for stable
operation and easy to use through the graphical touch-screen.
Up to four steps (or ramps) can be programmed (8 steps if only one
channel is used).
- No drift due to high stability, 0.01癈.
- No vibrations during imaging and recording - no internal fan
- Plastic-encapsulated external probes: no metal ions leakage into solutions
- Automatic cooling
- Self-tuning, no adjustments are required
- Multiple temperature sensors to choose for feedback, STAGE and
BATH
- Built-in overheating protection
- Inputs for programmed temperature changes
- Analog and Digital Outputs to monitor and SET temperature,
RS232 port
- Digital interface for software control
- No electrical noise - suitable for electrophysiology
Can be used with objective heaters and with
perfusion
systems: most heating stages work as inline solution
pre-heaters.
Specifications: |
Range: |
from -80 to 150癈 with accuracy 0.1癈 |
Stability: |
0.01癈 |
Built-in Temperature sensors: |
heating stages incorporate sensors for stable operation |
External Temperature probes: |
miniature 0.87mm diameter, fits small volume
chambers |
Settings: |
Self-tuning to stabilize temperature of different sample volumes and heating stage sizes, no manual adjustments are required;
input for an external SET temperature to program
protocols; software control |
Feedback: | From built-in STAGE or
BATH sensors |
Dimensions: |
14x6x8in. |
Input/Output: |
100-240VAC 230W/8A per channel,
230W (with 35V output) |
Click on catalog numbers below to purchase online.
Required accessories: heating or
cooling stages.
Includes connecting cables.
Might require an optional external probe (BATH).
Optional accessories: perfusion system,
flow control.
Sample publications:
1
Mitochondrial Ca2+ Uptake from Plasma Membrane Cav3.2 Protein Channels Contributes to Ischemic Toxicity in PC12 Cells.
Science Open, 18 March 2013;
Download PDF manual.
Download PDF catalog.
|
|
Bioscience Tools
ph: 010-6759703, fax: 010-6759703
email: chengyuan@bio-goods.com
|
PRICES AND OPTIONS |
TC2-80-150 |
|
2-Channel Bipolar Temperature Controller, with RS232
port, heating and cooling
|
TC-TP |
|
Miniature 0.87mm temperature Probe
|
TC2-TCR |
|
Connecting Cable Assembly an easy-disconnect
cable for TC2-80-150 controllers (included with the controller, x2 ). Can be also used to monitor
temperature through the second channel. A
heating element can be attached to the cable connector.
|
BTC-TCR |
|
Connecting Cable Assembly for controllers with automatic cooling
|
|
|