DeFelsko PRB200B-C Positector PRB200B Probe Ultrasonic Coating Thickness Gages for Non-Metal Substrates.

Measuring Range: 0.5 - 40 mils (13 - 1000 µm)


Probe Only

The DeFelsko PRB200B-C Positector 200 B Probe non-destructively measures a wide variety of applications using proven ultrasound technology. The PosiTector PRB200B-C model measures polymer coating on wood, plastic, etc.

  • Ready to measure – no calibration adjustment required for most applications
  • Solvent, acid, oil, water, and dust resistant – weatherproof
  • PosiTector interchangeable platform – attach any PosiTector probe to a single gage body
  • USB, WiFi, and Bluetooth connectivity to PosiSoft PC, Mac, and Smartphone software
  • Certificate of Calibration showing traceability to NIST or PTB included (Long Form)

Conforms to ASTM D6132 and ISO 2808


line
Models
line

Probe Only

PosiTector gage bodies are compatible with the full range of PosiTector 6000, 200, DPM, SPG, RTR, SST, SHD and UTG probes.

PRB200BPRB200CPRB200D
Application
Polymer coating on wood, plastic, etc.Coatings on concrete, fiberglass, etc.Thick, soft coatings like polyurea, asphaltic neoprene, very thick polymers
Measurement Range*
13 to 1000 μm
0.5 to 40 mils
50 to 3800 μm
2 to 150 mils
50 to 7600 μm
2 to 300 mils
Accuracy
± (2 μm + 3% of reading)
± (0.1 mils + 3% of reading)
± (2 μm + 3% of reading)
± (0.1 mils + 3% of reading)
± (20 μm + 3% of reading)
± (1 mils + 3% of reading)
Certifield Thikness Standard
STDA3STDP6

STDP1

*Range limits apply to polymer based coatings only. D probe polyurea range is 50 to 5000 μm (2 to 200 mils).


line
Videos
line

PosiTector 200 - Measuring Coating Thickness on Wood, Plastic, Concrete and More

line

Coating Thickness Instruments Overview

line

PosiTector 200 - Coating Thickness Measurement on Rough Surfaces

line
Related Products
line


DeFelsko PosiTector 200 
Ultrasonic Coating Thickness Gauge

  • Ultrasonic Coating Thickness Gauge for wood, concrete, plastic and more
  • Separate Probe
related

line

PRINTERBT
Bluetooth Printer

  • Battery-operated
  • Receives data via Bluetooth wireless technology
  • Prints readings and statistical summary
related

line
Downloads
line

DeFelsko PRB200B-C Positector PRB200B Probe Ultrasonic Coating Thickness Gages for Non-Metal Substrates - B1 Ordering Guide
DeFelsko PRB200B-C Positector PRB200B Probe Ultrasonic Coating Thickness Gages for Non-Metal Substrates - C1 Ordering Guide
DeFelsko PRB200B-C Positector PRB200B Probe Ultrasonic Coating Thickness Gages for Non-Metal Substrates - D1 Ordering Guide
DeFelsko PRB200B-C Positector PRB200B Probe Ultrasonic Coating Thickness Gages for Non-Metal Substrates - Instruction Manual
DeFelsko PRB200B-C Positector PRB200B Probe Ultrasonic Coating Thickness Gages for Non-Metal Substrates - Data Sheet
DeFelsko PRB200B-C Positector PRB200B Probe Ultrasonic Coating Thickness Gages for Non-Metal Substrates - Quick Guide


lineF.A.Q.line

Do your instruments require any formal training for use? Do you offer ‘demo’ models?

No. Our instruments are designed for simple operation, feature easy-to-use menus, both full and quick instruction manuals, and helpful videos. In lieu of demonstration models, we provide unlimited technical support via telephone and/or email, and a limited 30-day money back guarantee.

Is the PosiTector 200 calibrated at the factory?

The PosiTector 200 arrives fully calibrated and ready to measure. A Long-Form Certificate of Calibration traceable to NIST or PTB is included, which documents actual readings taken by your instrument at our calibration laboratory on standards traceable to a national metrology institute. Beware of ‘Certificates’ or ‘Certificates of Conformance’ offered by competitors. These typically do not include actual instrument readings, and are often insufficient to meet common quality requirements.

The PosiTector 200 is factory calibrated to measure most polymer coatings out of the box without calibration or adjustment. If required, a simple gage adjustment can be made to a coating sample of known thickness as close as possible in composition to the intended application. For best results, the thickness of the sample should be equal to or slightly greater than the maximum expected thickness of the coating to be measured.

Can the PosiTector 200 be used to measure coatings on metal substrates?

In many cases, yes! However, the following should be noted:

  • Metal Substrate Thickness: Because sound travels through metals approximately three times faster than it travels through most protective coatings, substrate thickness will largely determine the suitability of a particular coating thickness application for the PosiTector 200.
  • Gage Adjustment: Adjustment to the PosiTector 200 gage’s Hi Range to eliminate unwanted metal substrate back-wall echoes is typically required for improved measurement repeatability. This process of adjustment is simplified through the use of the PosiTector 200 Advanced gage’s Graphics Mode. Although a PosiTector 200 Standard gage model has the capability to accurately measure single coat applications and a total coating system thickness of multi-layer applications, we strongly recommend the use of a PosiTector 200 Advanced gage model for measurement on metal substrates.
  • Single Coat Applications: A minimum coating thickness of 13µm (0.5 mil) on a flat metal substrate with a minimum thickness of 1.25mm (50 mils) is usually required.
  • Multi-Layer Applications –
  1. Total thickness: In many circumstances, the total thickness of a multi-layer coating system over metal can be reliably measured. As in single coat applications, a minimum total coating system coating thickness of 13µm (0.5 mil) on a flat metal substrate with a minimum thickness of 1.25mm (50 mils) is usually required.
  2. Individual layers: The PosiTector 200 will measure the thickness of individual layers when each layer is thicker than 125µm (5 mils) and the metal substrate is thicker than 6mm (0.25”). A greater difference in the acoustic characteristics of each layer results in a greater likelihood of accurate individual layer measurement.

A PosiTector 6000 probe is generally recommended over a PosiTector 200 probe for measuring coating thickness on metal substrates because –

  • Lower cost
  • Larger selection of probes (none requiring the use of an ultrasonic couplant gel)
  • Greater accuracy
  • Unlike PosiTector 200 probes, adjustment is not required for most protective coating properties
  • Fully conform to international standards for measuring coating thickness over metal

What is couplant?Do I need to use it every time I take a reading?

Couplant is required for every reading in order to propagate ultrasound into the coating. Water is a suitable couplant for smooth coatings. Use the supplied glycol gel for rougher coatings.

Can the PosiTector 200 measure coatings that contain particles or aggregate?

Broadcast epoxy, urethane mortar and other coating systems that contain aggregates or particulate inclusions (silica, quartz flake, concrete, etc.) will present a significant measurement challenge to our ultrasonic PosiTector 200 instrument. This is caused by the tendency of the solid particles to interfere with the ultrasonic impulse and typically results in unreliable thickness readings.

How do I ‘Zero’ the PosiTector 200?

Unlike a magnetic or eddy-current principle gage, an uncoated substrate is not required to Zero the PosiTector 200. Instead, the probe is held in the air away from the substrate when the Zero is performed.

How often should the PosiTector probe be recalibrated?

PosiTector probes include a Certificate of Calibration with no expiry or end date. They have no shelf life, therefore the length of time in the field is not a good indicator for recalibration intervals. Many organizations with quality programs and recertification programs require annual recalibrations, and this is a good starting point for most users. DeFelsko recommends that customers establish calibration intervals based upon their own experience and work environment. Based on our product knowledge, data and customer feedback, a one year calibration interval from the date the instrument was placed in service is a good starting point.