Dansensor MAP Mix 9001 2/3 Gas Mixer for Buffer or Flow Applications
The Dansensor MAP Mix series is based on a proportional gas mixing principle especially designed for packaging machines and other industrial applications where the gases carbon dioxide, oxygen and the inert gases nitrogen and argon are used either in a 2-gas or 3-gas combination.
High volume gas users should also view the Dansensor MAP Mix Provectus (35-1500 L/min).

3 Gas Mixer (L) & 2 Gas Mixer (R)
The mixing principle of the MAP Mix series is very unique and can be used for all types of packaging machines, e. g. flow packaging machines and gas vacuum packaging machines. The Dansensor gas mixer is very user-friendly with high accuracy – also under conditions usually causing problems for the repeatability of most other mixers.
The mixer features detection of a “too low” gas inlet pressure with an alarm relay output to the external control.
- High accuracy for optimal mixing quality
- Proportional gas mixing principle
- Prepared for use with a microprocessor controlled gas analyser
- Very high flow rate
- Sturdy industrial design made in stainless steel/aluminium
- Easy mixture adjustment
- Optional ON/OFF solenoid valve for gas flow (to shut off the gas flow on flow packaging machines when the packaging machine stops)

MAP Mix 9001 – 2 Gas
Gas mixer/gas analyser
The standard version of the mixer can be used in conjunction with Dansensor’s online headspace gas analysers MAP Check 3 & MAP Check 3 VAC.
Flexible and ready to install
All our gas mixers will be delivered pre-adjusted and ready to install
Accuracy and optimal blending quality
The Dansensor MAP Mix series offers an unprecedented linearity in the flow range of 15-100% and mix settings of 10-90%.
Due to the design of the proportional pressure system, deviating pressure conditions on the inlet side have virtually no effect on the accuracy.
Mixing principle
All our mixers are utilising the advantage of proportional mixing, which means that the mixing is carried out via proportional pressures on the two sides of a diaphragm. This diaphragm ‘absorbs’ the deviation in the inlet pressure which normally is causing changes in the mixing conditions.

MAP Mix 9001 – 3 Gas
Technical specifications
General
- Accuracy: Better than +/- 2% absolute within a flow range of 15 – 100% and mix settings of 10 – 90%
- Pressure: See below. Flow shut off valve (optional/flow versions)
- Gas in / gas out: Rear panel
- Mixture adjustment: Manual
- Alarms: Inlet pressure alarm with visual indication per gas and signal out (contact relay) on the rear panel. Acoustic alarm for a too low gas inlet pressure
- Cabinet: Stainless steel
Configurations
Model / 9001 ME for thermoforming
and tray sealing machines: (Buffer) |
Max. outlet |
Inlet |
Cabinet dimensions:
(DxHxW) mm.
|
Approx. weight |
25-250L, 2-gas |
3.8 – 6.0 bar |
5.5 – 10 bar |
420x194x235 |
10.0 Kg. |
100-400L, 2-gas |
3.8 – 6.0 bar |
5.5 – 10 bar |
420x194x235 |
10.5 Kg. |
100-1000L 2-gas |
3.8 – 6.0 bar |
5.5 – 10 bar |
420x194x475 |
16.5 Kg. |
20-200L 3-gas |
2.8 – 5.0 bar |
5.5 – 10 bar |
420x194x235 |
12.0 Kg. |
100-400 3-gas |
2.8 – 5.0 bar |
5.5 – 10 bar |
420x194x475 |
17.0 Kg. |
Inlet Pressure |
Min 5.5 bar, Max 10 bar
The specific pressure interval is indicated on the mixer |
Outlet Pressure |
2 gas |
3.8 – 6 bar (55 – 87 psi) |
|
3 gas |
2.8 – 5 bar (41 – 73 psi) |
|
|
|
|
Model / 9001 ME for flow wrapping machines |
Inlet |
Cabinet dimensions:
(DxHxW) mm.
|
Approx. weight |
25-250L, 2-gas |
8.5 – 10 bar |
420x194x235 |
10.0 Kg |
100-400L, 2-gas |
8.5 – 10 bar |
420x194x235 |
10.5 Kg |
20-200L 3-gas |
8.5 – 10 bar |
420x194x235 |
12.0 Kg. |
100-400L, 3-gas |
8.5 – 10 bar |
420x194x475 |
17.0 Kg. |
Flow capacity for MAP Mix 9001 ME for buffer
The MAP mixers are delivered with standard inlet pressure 8.5-10 bar. Other settings are optional and has to be specified when ordering the gas mixer.
2 gas / 250 litre |
|
2 gas / 400 litre |
|
2 gas / 1000 litre |
Flow l/min |
Buffer tank pressure |
Inlet pressure |
2 bar |
3 bar |
4 bar |
5 bar |
6 bar |
5.5 – 7.0 bar |
132 |
84 |
|
|
|
6.5 – 8.0 bar |
183 |
145 |
90 |
|
|
7.5 – 9.0 bar |
226 |
220 |
170 |
110 |
|
8.5 – 10 bar |
262 |
257 |
221 |
190 |
120 |
|
|
Flow l/min |
Buffer tank pressure |
Inlet pressure |
2 bar |
3 bar |
4 bar |
5 bar |
6 bar |
5.5 – 7.0 bar |
267 |
187 |
|
|
|
6.5 – 8.0 bar |
346 |
287 |
185 |
|
|
7.5 – 9.0 bar |
453 |
418 |
345 |
236 |
|
8.5 – 10 bar |
505 |
480 |
434 |
332 |
198 |
|
|
Flow l/min |
Buffer tank pressure |
Inlet pressure |
2 bar |
3 bar |
4 bar |
5 bar |
6 bar |
5.5 – 7.0 bar |
655 |
427 |
|
|
|
6.5 – 8.0 bar |
853 |
732 |
442 |
|
|
7.5 – 9.0 bar |
1052 |
945 |
762 |
472 |
|
8.5 – 10 bar |
1219 |
1158 |
1036 |
808 |
442 |
|
|
|
|
|
|
|
|
|
|
|
3 gas / 200 litre |
|
3 gas / 400 litre |
|
|
Flow l/min |
Buffer tank pressure |
Inlet pressure |
2 bar |
3 bar |
4 bar |
5 bar |
6.5 – 8.0 bar |
145 |
104 |
|
|
7.5 – 9.0 bar |
207 |
183 |
141 |
|
8.5 – 10 bar |
235 |
217 |
185 |
127 |
|
|
Flow l/min |
Buffer tank pressure |
Inlet pressure |
2 bar |
3 bar |
4 bar |
5 bar |
6.5 – 8.0 bar |
285 |
205 |
|
|
7.5 – 9.0 bar |
400 |
345 |
245 |
|
8.5 – 10 bar |
444 |
400 |
325 |
176 |
|
|
 Buffer Tank |
Specifications subject to change without notice.
Buffer Tank – Option
The Dansensor stainless steel buffer tank is an option for the MAP Mix Provectus
and MAP Mix 9001 gas mixers.
- Can be combined with two, or more, buffer tanks to achieve a higher performance.
- Each tank has a volume of 15 litres and a maximum pressure of 10 bar.
- Can be either floor or wall mounted.
Case Study
MAP Case Study from Belgium Olive Packer
A high-grade olive packaging company opts for MAP solutions for quality control – including the Dansensor MAP Mix 9001
Related Products
MAP Check 3, MAP Check 3 Vacuum, MAP Mix Provectus
For more information,